ARMY TM 9-6115-60412NAVY NAVFAC P-8-633-121.HEXAGON HEAD CAPSCREW9.NUT AND CAPTIVE WASHER ASSEMBLY2.LOCKWASHER10.UTILITY POWER CIRCUIT BREAKER CB1253.CIRCUIT BREAKER ENCLOSURE COVER11.SET POWER CIRCUIT BREAKER CB1244.HEXAGON HEAD CAPSCREW12SCREW AND CAPTIVE WASHER ASSEMBLY5.LOCKWASHER13.FLAT WASHER6.CIRCUIT BREAKER SUPPORT14.SPACER7.PAN HEAD SCREW15.NUT AND CAPTIVE WASHER ASSEMBLY8.FLAT WASHER16CIRCUIT BREAKER LOCKING BEAMFigure 4-79. Utility/Set Circuit Breaker Assembly (Sheet 2 of 2)4-138. UTILITY STATION POWER TRANSFORMER T103 . UTILITY STATION POWER TRANSFORMER T103transforms 380 V ac to 120/240 V ac for distribution panel DP1 and DP2 and is located inside engine control cabinet C.Dangerous voltage levels may be present at components located within cabinet C.Observe all applicable safety precautions as outlined In Chapter 1, Section III , of thismanual.NOTEAll megohmmeter tests must be performed for 30 to 60 seconds.a.Test.(1)Tag and disconnect wiring from UTILITY STATION POWER transformer T103.(2)With multimeter set to RX10 scale, check continuity of primary winding across primary taps H1 andH2; and H2 and H3. Check continuity of secondary winding across secondary taps X1 and X2; andX2 and X3. Multimeter should read less than 10 ohms.(3)Connect a 500 V dc megohmmeter to either primary tap (H1 or H3) and to ground. Operate themegohmmeter for 60 seconds and observe resistance. Reading should not be less than 10megohms.(4)Connect the megohmmeter to either secondary tap (X1 or X3) and to ground Operate themegohmmeter for 60 seconds and observe resistance. Reading should not be less than 10megohms.(5)Connect a 500 V dc megohmmeter across the primary and secondary windings. Operate themegohmmeter for 60 seconds and observe resistance. Reading should not be less than 10megohms.(6)If UTILITY STATION POWER transformer T103 fails any test described above, refer to the nexthigher level of maintenance.(7)Connect wiring and discard tags.4-139. SET STATION POWER TRANSFORMER T101. SET STATION POWER transformer T101 transforms 2400 Vac to 120/240 V ac for distribution panels DP1 and DP2 and is also located In the rear compartment of cabinet C.Dangerous voltage levels may be present at components located within cabinet C.Observe all applicable safety precautions as outlined in Chapter 1, Section III, ofthis manual.a.Test.(1)Tag and disconnect wiring from SET STATION POWER transformer T101.(2)With multimeter set to RX1 scale, individually check continuity of transformer primary (H1 and H2terminals) and secondary (X1 and X2, X2 and X3 terminals) windings.4-200
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business