Figure 3-143. 400 Hz Generator Stator Winding Procedures (Sheet 3 of 3)
Figure 3-145. 400 Hz Generator Rotor Winding Procedures
TM-9-6115-464-34 Generator Set Diesel Engine Driven Tactical Skid Mtd 15 Kw 3 Phase 4 Wire 120/208 and 240/416 Volts Manual
Page Navigation
332
333
334
335
336
337
338
339
340
341
342
ARMY TM 9-6115-464-34
AIR FORCE TO 35C2-3-445-2
NAVY NAVFAC P-8-624-34
3.
4.
5.
6.
7.
8.
9.
10.
INTERPRET DRAWING PER MlL-STD-100.
STACK LAMINATIONS, FIND NOS. 1 AND 2,
ON I.D. UNDER 2.5 ± 10% TONS.
BRAZE CAGE ROD, FIND NO. 3, TO
LAMINATIONS, FIND NO. 1, IN
ACCORDANCE WITH MIL–B-7883. TYPE 1,
GRADE B, BRAZING
FLUX
SHALL BE IN
ACCORDANCE WITH AWS TYPE 3A.
ONE COIL SPACER SHALL BE USED AT
EACH OF EIGHT PLACES.
APPLY 4 LAYERS OF TAPE, FIND NO. 8, TO
SECURE CABLE STUDS.
APPLY 2 1/2 LAYERS OF TAPE, FIND NO.
12, TO ROD, FIND NO. 4.
VACUUM–PRESSURE IMPREGNATE IN
ACCORDANCE WITH 72–2487.
CLEAN CABLE STUDS AFTER
IMPREGNATION.
TORQUE
CAP SCREWS, FIND NO. 5, TO
17–FT–LB ± 10% WHILE THE
LAMINATIONS ARE UNDER PRESSURE.
GROUND INSULATION: GREATER THAN
200 MEGOHMS.
HIGH POTENTIAL: 1500 VOLTS.
Figure 3-144. 50/60 Hz
Generator
, Rewinding Procedures
3-303