ARMY TM 9-6115-464-34
AIR FORCE TO 35C2-3-445-2
NAVY NAVFAC P-8-624-34
Figure 3140. Lead Block Assembly, Exploded View
(30) If inspection reveals damage to the lead block assembly, disassemble as follows:
(a) Remove nuts (1, figure 3-140), Iockwashers (2) and screws (3).
(b) Separate pressure plates (4) and blocks (5, 6, and 7).
(31) If inspection reveals damage to stator assembly, disassemble as follows:
(a)
(b)
(c)
Remove screws (1, figure 3141) and Iockwashers (2) to remove ring (3). (400 Hz generator sets
only.)
Remove screws (4) and Iockwashers (5) to remove lead bushing (6).
Unscrew eye bolt (7) from frame assembly (8).
NOTE
Do not attempt to disassemble frame assembly.
c. Cleaning, Inspection, and Repair.
WARNING
Use solvent in a well ventilated area. Avoid inhaling solvent fumes. Do not allow
solvent to come into contact with the skin. Failure to observe this warning could result
in servere personal injury or death.
(1) Clean all generator parts using an approved solvent. Do not dip parts into solvent.