ARMY TM 9-6115-464-34
AIR FORCE TO 35C2-3-445-2
NAVY NAVFAC P-8-624-34
(8) Tighten locknut and remove hydraulic pump assembly from test hookup.
f. Installation.
(1) Install hydraulic pump assembly with gasket (4), flat washers (3), screws (2) and Iockwires (1).
(2) Install hydraulic lines and fittings onto hydraulic pump assembly.
(3) Refer to Operator and Unit Maintenance Manual to fill the hydraulic sump
3-85