ARMY TM 9-6115-464-12AIR FORCE TO 35C2-3-445-1NAVY NAVFAC P-8-624-12Step 1.Step 2.Step 3.Step 4.Step 5.Step 6.Step 7.Step 8.2-28DO NOT ATTEMPT TO OPERATE THE ELECTRIC WINTERIZATION KIT IFTHE GENERATOR SET IS EQUIPPED WITH A FUEL BURNING WINTERIZA-TION KIT WHICH IS OPERATING. EQUIPMENT DAMAGE COULD RESULT IFCAUTION IS NOT OBSERVED.NOTEREFER TO THE ELECTRIC WINTERIZATION SYSTEM DIAGRAM ANDINSTRUCTIONS PLATE LOCATED ON THE INSIDE FACE OF THE LEFT SIDEENGINE COMPARTMENT ACCESS DOOR FOR ADDITIONAL INFORMATION.IF THE GENERATOR SET IS EQUIPPED WITH A FUEL BURNING WINTERIZATION KIT, TURNTHE HANDLE OF THE THREE-WAY VALVE IN THE OIL PAN COOLANT LINE UNTIL THE POINT-ER IS IN THE 12 O’CLOCK POSITION.OPEN BOTH SHUTOFF VALVES IN THE CYLINDER BLOCK COOLANT LINES.DEPRESS THE CIRCUIT BREAKER TO ENERGIZE THE HEATER CONTROL CIRCUITS.DEPRESS POWER ON AND HEATER ON INDICATOR LIGHTS. IF THEY DO NOT ILLUMINATEWHEN DEPRESSED, NOTIFY HIGHER LEVEL MAINTENANCE.PLACE ON-OFF SWITCH IN THE ON POSITION. IF BOTH POWER ON AND HEATER ON lNDI-CATOR LIGHTS DO NOT ILLUMINATE, CHECK FUSE. IF FUSE IS SERVICEABLE, CHECK lNDl-CATOR LAMPS (paragraph 5-13d.). IF LAMPS ARE SERVICEABLE, CEASE OPERATION ANDNOTIFY HIGHER LEVEL MAINTENANCE.PRIOR TO STARTING THE GENERATOR SET, TURN THE THREE-WAY VALVE HANDLE UNTILTHE POINTER IS IN THE 9 O’CLOCK POSITION AND CLOSE BOTH SHUTOFF VALVES IN THECYLINDER BLOCK COOLANT LINES.PLACE THE ON-OFF SWITCH IN THE OFF POSITION.DO NOT START THE GENERATOR SET WHILE THE ON-OFF SWITCH IS INTHE ON POSITION. EQUIPMENT DAMAGE COULD RESULT IF CAUTION ISNOT OBSERVED.REFER TO PARAGRAPH 2-6 AND START THE GENERATOR SET.Figure 2-11. Operating the Electric Winterization Kit