ARMY TM 9-6115-464-12
AIR FORCE TO 35C2-3-445-1
NAVY NAVFAC P-8-624-12
Section Il. MAINTENANCE ALLOCATION CHART FOR 15KW, TACTICAL, PRECISE AND
UTILITY, 50/60 AND 400 HZ - Continued
(1)
GROUP
NUMBER
29
(2)
COMPONENT/
ASSEMBLY
Control Panel As-
sembly
Switch rotary
Semi-conductors
Transformers
Terminal Board
Diodes
Breakers, Circuit
Fan and Motor
Assembly
Brushes
Fan
Indicating Light
Lamp
Load Reject
Relay
Thermostat
Heater Elements
Applications Kit
(3)
MAINTENANCE
FUNCTION
Inspect
Test
Replace
Inspect
Test
Replace
Inspect
Test
Replace
Inspect
Replace
Test
Replace
Inspect
Test
Replace
Inspect
Test
Replace
Repair
Inspect
Replace
Inspect
Replace
Inspect
Test
Replace
Test
Replace
Inspect
Test
Replace
Test
Replace
Inspect
Test
Replace
Inspect
Install
Repair
(4)
MAINTENANCE LEVEL
C
UNIT
O
.1
.1
.2
.1
.1
.2
.1
.1
.2
.1
.2
.2
.3
.1
.3
.1
.3
.1
.1
.1
.1
.1
.1
.1
.2
.1
.2
.2
.1
DS
F
GS
H
DEPOT
D
(5)
TOOLS AND
EQUIPMENT
2
2
2
2
2
2
40,42,43,
44,45
(6)
REMARKS
F
F
I
F
F
F
A, J