ARMY TM 9-6115-464-12
AIR FORCE TO 35C2-3-445-1
NAVY NAVFAC P-8-624-12
Section Il. MAINTENANCE ALLOCATION CHART FOR 15KW, TACTICAL, PRECISE AND
UTILITY, 50/60 AND 400 HZ - Continued
(1)
(2)
(3)
(4)
(5)
(6)
MAINTENANCE LEVEL
GROUP
COMPONENT/
MAINTENANCE
UNIT
DS
GS
DEPOT
TOOLS AND
NUMBER
ASSEMBLY
FUNCTION
C
O
F
H
D
EQUIPMENT
REMARKS
Speed Switch and
Inspect
.1
2, 17, 18
F, U
Drive
Test
.2
Adjust
.3
Replace
.3
Repair
.3
Overhaul
1.0
Rebuild
2.0
Adapter
Inspect
.1
Replace
.2
Oil Level Gage
Inspect
.1
and Filler
Replace
.5
Electric Starter
and Adapter
Starter Assembly
Inspect
.1
2, 19
C, D
Test
.1
Replace
.2
Repair
.8
Overhaul
4.0
Rebuild
6.0
Brushes
Inspect
.2
V
Replace
.5
Starter, Solenoid
Test
.1
2
C
Replace
.3
Repair
.4
Starter, Armature
Test
.3
21
W
Replace
Repair
.3
Overhaul
2.0
Drive Starter
Inspect
.2
Replace
.3
Repair
.5
Field Assembly
Inspect
.1
Test
.2
Replace
.5
Repair
1.2
20
Oil Filters and
Sensors
XMTR, Pressure
Inspect
.1
2
F
Test
.2
Replace
.2
Switch Pressure
Inspect
.1
2
F
Test
.2
Replace
.3
B-11