TM 5-6115-593-12TO 35C2-3-463-1a.Cut two pieces of sleeving oneblack and one red 2 inches (5 cm)long, and place them over wireends.b.Attach terminal lug on end of wire thatwas previously stripped 0. 62 inch (15. 7mm). Orient the lug as shown, then crimpthe terminal securely.c.Attach battery terminal lug on other end ofwire. Orient the lug as shown, then crimpthe terminal securely.d.Push sleeving up to terminals and applyheat of 400°F (204°C) for 3 to 5 secondsto obtain proper shrinkage.4-16. BATTERIESWARNINGDo not smoke or use an open flame inthe vicinity when servicing batteries.Batteries generate a highly explosivehydrogengas during charging.Electrolyte is sulfuric acid diluted withwater and can cause severe acid burnswhen spilled on skin or clothing. Useextreme care in handling whileservicing batteries. When servicingbatteries reference TM9-6140-200-14.Figure 4-10. Battery Cable Fabrication4-36