a.
Cut two pieces of sleeving one
black and one red 2 inches (5 cm)
long, and place them over wire
ends.
b.
Attach terminal lug on end of wire that
was previously stripped 0. 62 inch (15. 7
mm). Orient the lug as shown, then crimp
the terminal securely.
c.
Attach battery terminal lug on other end of
wire. Orient the lug as shown, then crimp
the terminal securely.
d.
Push sleeving up to terminals and apply
heat of 400°F (204°C) for 3 to 5 seconds
to obtain proper shrinkage.
4-16. BATTERIES
WARNING
Do not smoke or use an open flame in
the vicinity when servicing batteries.
Batteries generate a highly explosive
hydrogen
gas
during
charging.
Electrolyte is sulfuric acid diluted with
water and can cause severe acid burns
when spilled on skin or clothing. Use
extreme
care
in
handling
while
servicing batteries. When servicing
batteries reference TM9-6140-200-14.
Figure 4-10. Battery Cable Fabrication
4-36