TABLE 2-1.
TOOLS AND SUPPORT EQUIPMENT, TEST, REPAIR CALIBRATION AND HANDLING (CONT)
NSN or
Item
Part No
AC Power Supply
17 BU-3 Superior
120/208 Vat, 3
Electric (58474)
Phase, 4 wire
(or equivalent)
60 HZ
C Voltmeter
Model 904 Weston
0-120 VAC
(65092) (or equiva-
lent)
Test stand Actua- 4940-00-152-2107
tor
(or equivalent)
AC Ammeter
Model 433
Weston (65092) or
equivalent
Test Set, Gen &
4910-00-092-9136
Voltage Regulator
(or equivalent)
Test Set, armature 6625-00-828-5810
(or equivalent)
Variable voltage Model 1308
Variable frequency General Radio
power supply (0-
(24655)
160) VAC, 20-450 (or equivalent)
Hz
REFERENCE___
Fig
3-4
8-11
8-8
8-19
8-21
13-3
8-11
14-2
14-11
8-8
8-9
8-12
8-12
8-13
8-14
7-3
7-4
7-5
7-5
7 - 7
7-8
7-9
Para
3-7
8-7
8-7
8-12
8-18
13-6
8-7
14-10
14-28
8-7
8-7
8-7
8-7
8-7
8-7
7-6
7-6
7-6
7-6
7-6
7-6
7-6
7-6
Use
Thermal watt converter testing
Overload relay test
Short circuit relay test
Excitation system assembly test
Load measuring unit test
Hydraulic actuator test
Overload relay test
Battery charging alternator in-
spection and test
Electric starter inspection and
test
Short circuit (Bench Test) relay
test (400HZ)
Overvoltage relay test
Underfrequency relay test (50/60
Hz)
Underfrequency relay test (400HZ
Undervoltage relay test (400 HZ)
Permissive parallel relay test
Electro-hydraulic governor
Magnetic amplifier bias test
50/60 HZ
Electro-hydraulic governor freq-
uency sensing test (50/60 Hz)
Electro-hydraulic governor re-
ctifier bridge and-feedback wind
ing test (50/60 Hz)
Electro-hydraulic governor paral-
lel winding test (50/60 Hz)
Electro-hydraulic governor mag-
netic amplifier bias test (400 H
Electro-hydraulic governor fre-
quency sensing test (400 Hz)
Electro-hydraulic governor rec-
tifier bridge and feedback winding
test (400 Hz)
Electro-hydraulic governor paral-
7-10
Change 3
2-5
lel winding test (400 Hz)