Table 8-1.
Relay Table Group Equipment Tests
Malfunctioning
Malfunction
On equipment test
assembly
Location
1. Main generator
Separately excite
a. Output normal.
a. Excitation
a. Relay table
output too low,
field with dc
system
group.
too high, or
power supply.
assembly.
failure to
flash.
b. Output low,
b. Generator
b. Generator
high, or
assembly.
assembly.
will not
flash.
2. Generator runs at
Place battle
a. Overload
a. Overload
a. Tactical relay
less than 130
short switch
indicator
relay.
box.
percent of rated
in on posi-
lights and
current for 10
tion.
CB2 remains
minutes; CB2
close.
drops out and
overload indi-
b. Unit operates
b. See table 2-2.
b. See table 2-2.
cater lights.
normally.
3. Generator runs at
Place battle short switch in on
Overvoltage relay.
Tactical relay
normal voltage,
position; overvoltage indicator
box.
set shuts down
lights but the set does not
and overvoltage
shut down.
indicator lights.
4. Generator runs at
Place battle short switch in on
Undervoltage
Mode I - Precise
rated voltage,
position; undervoltage indicator
relay.
relay box.
CB2 drops out
lights and CB2 remains
and undervoltage
close.
Mode 11- Special
indicator lights.
relay box.
5. Generator runs at
None required.
Short circuit
Tactical relay
rated load, CB2
relay.
box.
drops out, and
short circuit in-
dicator lights.
6. Generator runs at
Place battle short switch in on
Reverse power
Mode I - Precise
rated load, CB2
position; reverse power indi-
relay.
relay box.
drops out, and
cater lights and CB2
reverse power
remains close.
Mode XI - Special
indicator lights.
relay box.
7. Generator runs at
Place battle short switch in on
Permissive
Mode I - Precise
rated load, CB2
position; unit operates nor -
parallel
relay box.
drops out with no
mally.
relay.
malfunction indi-
Mode II- Special
cated.
relay box.
B. Generator runs at
Place battle short switch in on
Under frequency
Mode I - Precise
rated frequency,
position; underfrequency indi-
relay.
relay box.
CB2 drops out,
cater lights and CB2
and underfreq-
remains close
Mode II - Special
uency indicator
relay box.
lights.
8-2