Overshoot/undershoot:
Starter Assembly Classification and Rating.
c.
MEP-005A . . . . . . . 20% rated voltage
Stalled current . . . . . . 500 amps (max)
MEP-104A . . . . . . . 15% rated voltage
Stalled torque . . . . . . 18 lbs. - ft. (min)
MEP-114A . . . . . . . 12% rated voltage
Duty classification . . . . 15 sec on - 15 sec off
(2 starting cycles per
f. Governor Control Unit Classification and
minute)
Rating.
Drive type . . . . . . . . Positive indexing with
DOD Drawing Numbers:
overrun clutch
50/60 Hz . . . . . . . . 69-784-2
d. Fuel Injector Pump Classification and
Rating.
400 HZ . . . . . . . . .81-49O3
Type . . . . . . . . . . .Solid state
Manufacturer . . . . . . . Hartford Machine Screw
Co., Div. of Standard
Input volts . . . . . . . . 24 Vdc and 120 Vac
Screw Co., Inc.
Model . . . . . . . . . . . DBGFC633X1LK
Line pressure . . . . . . . . 2500 to 2950 psig
Enclosure . . . . . . . . . Water-proof, wax-filled
Transfer pump pressure. . . 130 psig (max)
casing
Transfer pump lift . . . . 15 in. HG (min)
f.1 Governor Control Kit Classification and
Rating.
Full load rpm . . . . . . .l8OO
Delivery variation
DOD Drawing numbers:
between cylinders at
Governor control unit . . . 81-4903
full load . . . . . . . . 5% (max)
Magnetic actuator . . . . . 81-705
e. Static Exciter and Voltage Regulator
Magnetic pickup . . . . . . 81-4904
Assembly Classification and Rating.
Solid state
Type . . . . . . . . . . . Solid state
Type:
Voltage regulation:
Input volts . . . . . . . . 11-40 Vdc
MEP-005A . . . . . . . . 3% of rated voltage
MEP-104A . . . . . . . . 1% of rated voltage
Temperature range . . . . . -65 to 185F
(-55 to 85C)
MEP-114A . . . . . . . . 1% of rated voltage
9" Overvoltage Relay Classification and
Voltage stability:
Rating.
Short term:
DOD Drawing number . . . . 72-2257
MEP-005A . . . . . . . Within 2% of rated
Nominal voltage . . . . . . 120 Vac
voltage
Actuation voltage . . . . . 153 3 Vac over fre-
MEP-104A . . . . . . . Within 1% of rated
quency range of 50 to
voltage
450 Hz
MEP-114A . . . . . . . Within 1% of rated
Time delay . . . . . . . . 200 m sec sustained
voltaqe
overvoltage (rein)
Long term:
Trip time . . . . . . . . . Less than 1.0 sec.
MEP-005A . . . . . . . Within 4% of rated
after sustained pull-
voltage
in voltage
MEP-104A . . . . . . . Within 2% of rated
Contact rating . . . . . . 10 drop, 28.5V,
Voltage
resistive
MEP-114A . . . . . . . Within 2% of rated
Temperature range . . . . . -65F (-58.5C) to
voltaqe
+ 170F (76.7C)
Voltage drift (8 hour
h. Undervoltage Relay Classification and
period, with tempera-
Rating.
ture variation of up
. . . . 70-1120
DOD drawing number
to 60F)(15.5C) . . . . 1%
Nominal voltage . . . . . . 120 Vac
Transient performance:
Frequency range . . . . . . 50 to 450 Hz
Resumption of steady state:
. . . . . 99 4 Vac
Drop-out voltage
MEP-005A . . . . . . . Within 3 sec.
Pull-in voltage . . . . . . 110 3 Vac
MEP-104A . . . . . . . Within O.5 sec.
Time delay . . . . . . . . 6 2 sec. after drop-
MEP-114A . . . . . . . Within O.5 sec.
it (instantaneous at
40 Vac and below)
Change
5