h. Inspect paint for damage.
6-217.
INSPECTION.
6-218.
REPAIR.
a. Inspect wire for defective insula-
a. Repair defective wiring by remov-
tion. Check each wire to connector pin for
ing defective wire from connector and in-
stalling wire of same size and length in its
shorts to case and surrounding pins. In-
place.
spect connector for damaged threads.
b.
Chase damaged threads.
b . Check forward and reverse resis-
tance of diodes. Measured from anode (+)
c.
Repair cracked sheet metal parts
to cathode (-) value should be low, reverse
by welding. Straighten dented or distorted
meter leads value should be infinity.
parts using suitable tools.
c. Check resistor for proper ohmic
d. Fasten loose nameplate to cover
value, resistor should be adjustable from
using a suitabe adhesive.
0 to 500 ohms.
e. Remove damaged paint. Blend in
edges, prime, and paint damaged areas.
defective insulation, and missing terminals.
6-219.
REASSEMBLY.
e. Inspect threads for damage.
assemble the load mea surement unit in the
f. Inspect sheet metal parts for cracks,
reverse order of index numbers assigned.
dents, and distortion.
a. Solder diodes (19) and wires to
Inspect nameplate for security and
g.
6-184