TM 5-6115-275-24 P/NAVFAC P-8-615-24P/TO 35C2-3-452-4RecoverabilityCodesDefinitionDReparable item. When beyond lower level repair capability,return to depot. Condemnation and disposal notauthorized below depot level.LReparable item. Repair, condemnation and disposal notauthorized below depot/specialized Repair Activity level.AItem requires special handling or condemnation procedurebecause of specific reasons (i.e., precious metal content,high-dollar value, critical material or hazardousmaterial). Refer to appropriate manuals/directives forspecific instructions.c. (USMC) Special Stockage Indicator Code andReplacement Factor (Column 3). (Not Applicable)d. (ALL) National Stock Number (Column 4). I n d i-cates the National Stock Number assigned to the itemand will be used for requisitioning purposes.e. ( A L L ) D e s c r i p t i o n , Indicates the Federal itemname and any additional descriptions of the item re-quired. The abbreviation “w/e” when used as part ofthe nomenclature, indicates that the National StockNumber includes all armament, equipment, accessoriesand repair parts issued with the item. Apart number orother reference number is followed by the applicablefive digit Federal Supply Code for manufacturer inparentheses. If two reference numbers and FederalSupply Codes for manufacturer are listed, the first list-ing refers to the Department of Defense Drawing Num-b e r , t h e s e c o n d l i s t i n g r e f e r s t o t h e a c t u a l p a rtmanufacturer. Items that are included in kits and setsare listed below the name of the kit or set with thequantity of each item in the kit or set indicated in thequantity incorporated in unit column.f. (ALL) Unit of Measure (U/M). Indicates thestandard of the basic quantity of the listed item as usedin performing the actual maintenance function. Thismeasure is expressed by a two-character alphabeticalabbreviation (e.g., ea, in, pr, etc.). When the unit ofmeasure differs from the unit of issue, the lowest unitof issue that will satisfy the required units of measurewill be requisitioned.g. (ALL) Quantity Incorporated in Unit Indicatesthe quantity of the item used in the assembly group. A“V” appearing in this column in lieu of a quantity in-dicates that a definite quantity cannot be indicated(e.g., shims, spacers, etc.).4 . S p e c i a l I n f o r m a t i o n .a. (ALL) Identification of the usable on codes of thispublication are:CodeUsed OnADOD Model MEP-018ADOD Model MEP-023ARepair parts not symbolized are applicable to allmodels covered in this manual.b. (Army) Parts which require manufacture or as-sembly at a level higher than that authorized for in-stallation will indicate in the source column, the higherc. Stockage Information.(1) Air Force stockage information is contained inInitial Supply Support Lists issued separately fromthis publication by Sacramento Air Logistics Center inaccordance with AFM 67.1, part 1, chapter 12.(2) Navy stockage objectives are contained inConsolidated Shipboard Allowance List as furnishedseparately from this publication by the Ship Parts Con-trol Center.5 . H o w t o L o c a t e R e p a i r P a r tsa. (ALL) When National Stock Number or referencenumber is unknown:(1) Using the table of contents, determine thefunctional group; i.e., batteries and related parts, ex-haust and breather pipes, within which the repair partbelongs. This is necessary since illustrations are pre-pared for functional groups, and listings are dividedinto the same groups.(2) Find the illustration covering the functionalgroup to which the repair part belongs.(3) Identify the repair part on the illustration andnote the illustration figure and item number of therepair part.(4) Using the Repair Parts Listing, find the figureand item number noted on the illustration.b. (ALL) When National Stock Number or referencenumber is unknown:(1) Using the Index of National Stock Numbersand Reference Numbers, find the pertinent NationalStock Number or reference number. This index is in as-cending NSN sequence followed by a list of referencenumbers in alphanumeric sequence, cross-referencedto the illustration figure number and item number.(2) After finding the figure and item number,locate the figure and item number in the repair partslist.6 . A b b r e v i a t i o nsAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .alternating currentAMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . amperageAWG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .American Wire GageBRS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . brassCAD PLD. . . . . . . . . . . . . . . . . . . . . . . . . . .cadmium platedCD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .circuit descriptionCRES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .corrosion- resistantsteelCS . . . . . . . . . . . . . . . . . . . . . . . . . . . . .caseDC . . . . . . . . . . . . . . . . . . . . . . . . . . .direct currentDIA. . . . . . . . . . . . . . . . . . . . . . . . . . . .diameterEA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .eachGPH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .gallons per hourID. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . inside diameterIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . inch(s)INTL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . internalLG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .long, lengthLH. . . . . . . . . . . . . . . . . . . . . . .left handMM. . . . . . . . . . . . . . . . . . . . . .millimeterMTG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .mountingNOM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .nominalBlevel.NPT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .National taper pipeV
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business