LUBRICATION ORDER
LO 5-6115-614-12
AND OIL ANALYSIS
LI-07536B-12
15 OCTOBER 1986
DRIVEN, TACTICAL SKID MTD. 200 KW.
3 PHASE, 4 WIRE, 120/208 AND
240/416 VOLTS
DOD MODEL
CLASS
HERTZ
NSN
MEP009B
UTILITY
50160
Reference: C1900-IL
directed by a Army Oil Analysis Program (AOAP)
Intervals (on-condition or fixed time) and the related man-
Laboratory which has analyzed the oil for serviceability.
hour time are based on normal operation. The man-hour
time specified is the time needed to do all the services
Clean fittings with an approved solvent before lubricating.
prescribed for a particular interval. On-condition (OC) oil
Dotted lines indicate lubrication points on both sides of
sample interval shall be applied unless changed by the
the equipment, and lubrication points not visible from a
Army Oil Analysis Program (AOAP) Laboratory. Change
top view.
the fixed time Interval if lubricants are contaminated or if
equipment is functioning under adverse operating
Relubricate after washing.
conditions, including longer-than-usual operating hour.
The fixed time interval may be extended during periods of
The lowest level of maintenance authorized to lubricate a
low activity.
It extended adequate preservation
point is indicated by one of the following symbols as
precautions must be taken. Fixed time intervals will be
appropriate:
Operator/Crew (C), and Organizational
applied in the event AOAP laboratory support is not
Maintenance (O).
available.
Drain crankcase when hot. Fill and check level.
On-condition (OC) AOAP Laboratory determined oil
change intervals shall be applied instead of fixed time
Change the engine oil whenever the engine has been in
intervals such as hourly, calendar, or mileage, unless
an overheated condition.
otherwise notified. The services will be required when
CARD 1 OF 2