-KEY-
.
EXPECTED TEMPERATURES
LUBRICANTS
CAPACITY
+40 F to -10 F 0 F to -65F INTERVALS
Above +32 F
0 C
Intervals
+ 5 C to -23 C-180 C to -500 C
OE/HDO LUBRICATING OIL, Engine
given are
in hours of
normal
Crankcase
34-3/4 qt (33.02L)
operation.
Air Cleaners
11/2 qt. ea. (1.43L)
OE/HDO 30
OIE/HDO 10
OEA
Oil Can Points
OEA-OIL, Engine, Arctic
GAA-GREASE, Automotive and Artillery
ALL TEMPERATURES
NOTES:
Copy of this Lubrication Order will remain with the
equipment at all times; instructions contained herein are
1. FOR OPERATION OF EQUIPMENT IN
PROTRACTED COLD TEMPERATURES BELOW -10.
mandatory.
(-23 c). Remove lubricants prescribed in the key for
temperatures above -10 F. (-23
C). Clean parts
with SOLVENT, dry-cleaning. Relubricate with lubricants
specified in the key for temperatures below -10 F. (-23
C).
2. OIL FILTERS. After installing new filter elements, fill
By Order of the Secretary of the Army:
crankcase, operate engine 5 minutes, check housings
for leaks, check crankcase oil level and bring to full
mark.
FRED C. WEYAND
General, United States Army
Chief of Staff
3. OIL CAN POINTS. Every 50 hours lubricate hinges,
latches, control linkages, and all exposed adjusting
threads with OE/HDO.
4. FAN BEARING. Remove both plugs, insert fitting,
lubricate until new grease extrudes from relief plug hole,
operate engine at slow idle speed 3 minutes, install both
plugs.
5. LUBRICANTS. The following is a list of lubricants
with the Military Symbols and applicable Specification
numbers.
Official:
OE/HDO
MIL-L-2104
PAUL T. SMITH
OEA
MI L-L-46167
Major General, United States Army
GAA
MIL-G-10924
The Adjutant General
Distribution: To be distributed in accordance with DA
From 12-25D, (qty rqr block no. 1065). Operator
* U.S. GOVERNMENT PRINTING OFFICE: 1995 0 -
maintenance requirements for Generator Sets, , Engine
386730 (21305)
Driven, 100 KW, 60HZ, Precise Power.
PIN: 020575-000