• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Operator Preventive Maintenance Checks and Services - continued - TM-9-6115-660-13P_47
Operator Preventive Maintenance Checks and Services - continued - TM-9-6115-660-13P_49

TM-9-6115-660-13P Power Plant Diesel Engine Driven 1-Ton Trailer Mounted (With Racks) 3Kw 60 Hz AN/MJQ-42 Manual
Page Navigation
  18    19    20    21    22  23  24    25    26    27    28  
TM 9-6115-660-13&P Table 2-2.  Operator Preventive Maintenance Checks and Services - continued Location Item Interval Procedure Not Fully Mission No. Item to Capable if: Check/Service 7 Before DRAWBAR RING    Check drawbar ring (13) for secure Ring is loose or mounting and obvious damage bent. 8 Before INTERVEHICULAR a.   Check intervehicular cable (14) for cuts Cable is severed or CABLE and breaks missing. b Open protective cover (15) Inspect for broken, missing, and burnt pins (16). 9 Before SAFETY CHAINS Check safety chains (17) for secure Chain is missing or mounting and obvious damage unsecured. 10 Before AIR HOSE AND a With trailer hooked to towing vehicle, Air leaks are found COUPLER check air hose (18) for leaks, cuts, and or hose is cut deep (AN/MJQ-37 AND abrasions. enough for cords to AN/MJQ-38 ONLY) show. b Check coupler body (19) for damage Coupler body is Check if seal (20) is missing or cracked or broken. damaged Seal is missing. 2-14  Change 2